Features:
- Creatinine accuracy comparable to hospital laboratory testing
- Estimated glomerular filtration rate (eGFR) by MDRD and Cockcroft-Gault equations
- Simple test procedure
- Virtually painless, finger stick capillary blood sample, 1.2 ul
- Fast, 30 seconds creatinine and eGFR results
- Wide measurement range: 27 umol/L to 1056 umol/L (0.3-12 mg/dL)
- Cleared for use by point-of-care personnel
Tests:
Tests Measured: Creatinine and Hematocrit
Test Reported: Creatinine and eGFR
Test Time: 30 seconds
Test Strip Volume: 1.2 µL
Test Methodology: Electrochemistry
Weight: 0.8 lbs (360 g)
Size: 6.0 in x 3.25 in x 1.8 in (153 mm x 82.5 mm x 46 mm)
Selectable eGFR Calculation Equations:
MDRD, IDMS traceable MDRD, Schwartz, Counahan-Barratt and Cockroft-Gault
Sample Types & Operating Modes:
Whole Blood: Arterial, Venous, Capillary
Measurement Range:
Creatinine 0.3-12.0 mg/dl (27-1056 µmol/L)
Operating Ranges:
Temperature: 15°C- 40°C (59°F-104°F)
Altitude: Up to 15,000 feet
Humidity: 10% to 90% relative humidity
Data Storage:
Patient Tests: 1,000 tests
QC Tests: 200 tests
Users: 4,000 users
Connectivity:
Data Output Port: Etherent (10 Mbit)
Meter Data Output: RJ-45 Ethernet Port
Protocol: TCP/IP Ethernet 10 Mbit
Standard: POCT1-A Compliant
Setup Program: NovaNet™ Web-Based Instrument Manager Software
Battery Information:
Type: 3.7V Li Polymer Rechargeable Battery
Features: Rechargeable/Replaceable
Life: 8 hours in use (approximately 40 tests w/barcode scans) / 12-24 hours standby
Docking Station:
Optional accessory; desk or wall mount charging station
with RJ-45 Ethernet jack. 3 LED indicator lights showing
connection status, transmit/receive data, and charging status.
Extra battery slot included for recharging and storage of spare battery.
Reagents and Strips:
Strips: 25 strips per vial
QC: Three levels (Low, Normal, High);
sold separately
Linearity: Five levels available
Test Strip & QC Stability:
12 months (4-8°c)
3 months open-vial stability
Additional Features:
|
- Color touch screen
- Built-in barcode scanner
- Traditional QC with target values assigned to QC materials
- Numeric or pass/fail QC
- QC prompting or QC lock out
- Abnormal and critical ranges flagged by color highlighting
- Canned or free text user comments
- Rejecting of results at meter (optional) for repeat testing
- Accepting patient ID or accession number
- Use of operator password (lockout)
- Entry of ICD-9 Diagnosis codes
- Ordering physicians I.D.
- Slope and intercept adjustment
- Custom, web-based meter configuration by location
- Connect to hospital ADT
- Connect to all LIS/EMR
- POCT1-A data output
- Optional Carrying Case
|
|